230 research outputs found

    Aktuelle Entwicklungen und Herausforderungen der Computertomographie auf den Gebieten der Notfall- und kardiovaskulären Bildgebung

    Get PDF

    State of the art: iterative CT reconstruction techniques

    Get PDF
    Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limitations in CT imaging

    Radiation Dose and Fluoroscopy Time of Endovascular Treatment in Patients with Intracranial Lateral Dural Arteriovenous Fistulae

    Get PDF
    Purpose. Intracranial lateral dural arteriovenous fistula (LDAVF) represents a specific subtype of cerebrovascular fistulae, harboring a potentially life-threatening risk of brain hemorrhage. Fluoroscopically guided endovascular embolization is the therapeutic gold standard. We provide detailed dosimetry data to suggest novel diagnostic reference levels (DRL). Methods. Retrospective single-center study of LDAVFs treated between January 2014 and December 2019. Regarding dosimetry, the dose area product (DAP) and fluoroscopy time were analyzed for the following variables: Cognard scale grade, endovascular technique, angiographic outcome, and digital subtraction angiography (DSA) protocol. Results. A total of 70 patients (19 female, median age 65 years) were included. Total median values for DAP and fluoroscopy time were 325 Gy cm2 (25%/75% percentile: 245/414 Gy cm2) and 110 min (68/142min), respectively. Neither median DAP nor fluoroscopy time were significantly different when comparing low-grade with high-grade LDAVF (Cognard I + IIa versus IIb–V; p > 0.05, each). Transvenous coil embolization yielded the lowest dosimetry values, with significantly lower median values when compared to a combined transarterial/transvenous technique (DAP 290 Gy cm2 versus 388 Gy cm2, p = 0.031; fluoroscopy time 85 min versus 170 min, p = 0.016). A significant positive correlation was found between number of arterial feeders treated by liquid embolization and both DAP (rs = 0.367; p = 0.010) and fluoroscopy time (rs = 0.295; p = 0.040). Complete LDAVF occlusion was associated with transvenous coiling (p = 0.001). A low-dose DSA protocol yielded a 20% reduction of DAP (p = 0.021). Conclusion. This LDAVF study suggests several local DRLs which varied substantially dependent on the endovascular technique and DSA protocol

    Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size

    Get PDF
    Objective: The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. Methods: Thirty-six patients receiving chest CTaccording to 3 protocols (120 kVp/noise index [NI], 60;100 kVp/NI, 65;80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity;the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. Results: Diagnostic images (lesion conspicuity, 95%-100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. Conclusions: Model-based algorithm allows for submillisievert chest CT in average patients;the use of 100 kVp is recommended

    Incidence of delayed and missed diagnoses in whole-body multidetector CT in patients with multiple injuries after trauma

    Get PDF
    Background: Whole-body CT (WBCT) is the imaging modality of choice during the initial diagnostic work-up of multiple injured patients in order to identify serious injuries and initiate adequate treatment immediately. However, delayed diagnosed or even missed injuries have been reported frequently ranging from 1.3% to 47%. Purpose: To highlight commonly missed lesions in WBCT of patients with multiple injuries. Material and Methods: A total of 375 patients (age 42.8 +/- 17.9 years, ISS 26.6 +/- 17.0) with a WBCT (head to symphysis) were included. The final CT report was compared with clinical and operation reports. Discrepant findings were recorded and grouped as relevant and non-relevant to further treatment. In both groups, an experienced trauma radiologist read the CT images retrospectively, whether these lesions were missed or truly not detectable. Results: In 336 patients (89.6%), all injuries in the regions examined were diagnosed correctly in the final reports of the initial CT. Forty-eight patients (12.8%) had injuries in regions of the body that were not included in the CT. Fourteen patients (3.7%) had injuries that did not require further treatment. Twenty-five patients (6.7%) had injuries that required further treatment. With secondary interpretation, 85.4% of all missed lesions could be diagnosed in retrospect from the primary CT data-set. Small pancreatic and bowel contusions were identified as truly non-detectable. Conclusion: In multiple traumas, only a few missed injuries in initial WBCT reading are clinically relevant. However, as the vast majority of these injuries are detectable, the radiologist has to be alert for commonly missed findings to avoid a delayed diagnosis

    Perivascular vital cells in the ablation center after multibipolar radiofrequency ablation in an in vivo porcine model

    Get PDF
    Multibipolar radiofrequency ablation (RFA) is an advanced ablation technique for early stage hepatocellular carcinoma and liver metastases. Vessel cooling in multibipolar RFA has not been systematically investigated. The objective of this study was to evaluate the presence of perivascular vital cells within the ablation zone after multibipolar RFA. Multibipolar RFA were performed in domestic pigs in vivo. Three internally cooled bipolar RFA applicators were used simultaneously. Three experimental settings were planned: (1) inter-applicator-distance: 15 mm; (2) inter-applicator-distance: 20 mm; (3) inter-applicator-distance: 20 mm with hepatic inflow occlusion (Pringle maneuver). A vitality staining was used to analyze liver cell vitality around all vessels in the ablation center with a diameter>0.5 mm histologically. 771 vessels were identified. No vital tissue was seen around 423 out of 429 vessels (98.6%) situated within the central white zone. Vital cells could be observed around major hepatic vessels situated adjacent to the ablation center. Vessel diameter (>3.0 mm; p<0.05) and low vessel-to-ablation-center distance (<0.2 mm; p<0.05) were identified as risk factors for incomplete ablation adjacent to hepatic vessels. The vast majority of vessels, which were localized in the clinically relevant white zone, showed no vital perivascular cells, regardless of vessel diameter and vessel type. However, there was a risk of incomplete ablation around major hepatic vessels situated directly within the ablation center. A Pringle maneuver could avoid incomplete ablations

    Social origin, schooling and individual change in intelligence during childhood influence long-term mortality: a 68-year follow-up study

    Get PDF
    Background Intelligence at a single time-point has been linked to health outcomes. An individual's IQ increases with longer schooling, but the validity of such increase is unclear. In this study, we assess the hypothesis that individual change in the performance on IQ tests between ages 10 and 20 years is associated with mortality later in life
    • …
    corecore